Bore Water Reverse Osmosis Pre-Treatment, Australia
Continuous Ionic Filtration
INDUSTRY
Groundwater / Irrigation
LOCATION
Victoria, Australia
FLOWRATE
600 m3/day
COMISSIONED
2010
Summary
Clean TeQ Water provided a water treatment plant consisting of CIF® and reverse osmosis to provide additional water capacity for a golf course in Australia. The golf course was located in an area experiencing water shortages and the application to purchase additional potable water was rejected. The golf course opted to install the CIF® + RO system to treat the groundwater, as it greatly increased the treated water volume and reduce the size of the brine disposal pond required on site.
Water Quality
Species | Unit | Bore 1 | Bore 2 |
Flowrate | m3/day | 690 | 260 |
TSS | mg/L | 30.5 | 46.9 |
TDS | mg/L | 6227 | 6893 |
pH | - | 7.1 | 6.9 |
Cl | mg/L | 2450 | 3520 |
SO4 | mg/L | 391.9 | 327.9 |
TH (as CaCO3) | mg/L | 1018.63 | 2156.38 |
Ca | mg/L | 88 | 133 |
Fe | mg/L | 0.8 | 1.02 |
Mg | mg/L | 194 | 443 |
Sr | mg/L | 1.45 | 2.04 |
Ba | mg/L | 0.018 | 0.038 |
Mn | mg/L | 0.04 | 0.01 |
Na | mg/L | 1615 | 1851 |
Turbidity | NTU | 8.62 | 16.7 |